OPC-UA (IEC 62541) & Modbus TCP/IP

Industrial HMI Telemetry on Android

Engineered for automation technicians and commissioning engineers. Real-time machine monitoring, setpoint control, Control Word bit extraction, and fail-safe watchdog supervision with zero cloud dependencies.

✓ 100% On-Device Socket Client ✓ Zero Cloud Intermediaries ✓ Hardware KeyStore PKI
ONLINE • 10.0.2.2:502
PRO (BETA)
Speed Setpoint vs Actual PV HR:0.F & HR:2.F
SP: 50.0% PV: 49.8 m/s
Drum Speed
50.0 %
Line Tension (CDAB)
25.40
kilonewtons (kN)
Control Word [40008] MUTEX RMW ACTIVE
CAPABILITIES

Built for Real Industrial Environments

No compromises. Direct socket communication engineered for factory floors, marine subsea units, and remote SCADA sites.

OPC-UA (IEC 62541)

Connect with Anonymous or User/Password authentication across None and Basic256Sha256 encrypted profiles with hardware KeyStore X.509 certificates.

Modbus TCP / IP (Port 502)

Full support for Coils (0x), Discrete Inputs (1x), Input Registers (3x), and Holding Registers (4x). Supports Big-Endian Floats, Word-Swapped Floats, and 32-bit Integers.

Control Word Bit Extraction

Extract single bits from packed 16-bit words or registers into dedicated momentary or toggle buttons with thread-safe Read-Modify-Write (RMW) mutexes.

Fail-Safe Watchdog Supervisor

Sends periodic heartbeat pulses (100ms - 5s) to target boolean/integer registers. Watchdogs remain disarmed by default and disarm automatically upon disconnect.

Offline Design Studio

Build, arrange, and pre-map dashboard widgets without a live PLC connection. Export and import entire machine profiles as standalone .json files.

100% Private & Cloud-Free

Zero third-party telemetry, ads, or analytics tracking. All credentials and network packets remain strictly between your device and your machine.

SYNTAX & ADDRESSING

Flexible Tag Mapping Notation

OpcVue supports standard industrial addressing formats out of the box.

Tag Format Protocol Data Type Description
40001.F or HR:0.F Modbus Float32 (ABCD) Holding Register at offset 0, Standard Big-Endian Float
40011.FS or HR:10.FS Modbus Float32 (CDAB) Word-Swapped Little-Endian 32-bit Float
40013.I32 or HR:12.INT32 Modbus Int32 (DWORD) Signed 32-bit integer spanning 2 registers
40015.INT or HR:14.INT16 Modbus Int16 (Signed) Signed 16-bit integer (-32768 to +32767)
00001 or C:0 Modbus Boolean Coil Output (FC 01 / FC 05)
2:40001.F Modbus Float32 (Slave 2) Slave ID 2 Unit Override on Holding Register 40001
ns=2;s=Drive.Speed_RPM OPC-UA Double / Float OPC-UA String Node Identifier
ns=1;i=1004 OPC-UA UInt16 / Packed OPC-UA Numeric Node Identifier with Bit Extraction

Industrial Grade Security Architecture

Engineered for defense-in-depth isolation in critical infrastructure.

Direct TCP Socket Architecture

All network traffic travels directly between your device and the configured PLC endpoint over LAN, Wi-Fi, or VPN.

Hardware KeyStore Encryption

Project passwords, security tokens, and X.509 private keys are encrypted using AES-256 GCM backed by the Android Hardware KeyStore.

Zero Cloud Data Collection

No user accounts required. No analytics scripts. No telemetry logging to third-party databases.

Fail-Safe Disarm on Timeout

Active watchdogs and momentary write buttons instantly disarm and release upon socket drops or application backgrounding.

Ready to Monitor Your Machine?

Download OpcVue for Android on Google Play and start monitoring your industrial telemetry today.